Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
2.
Endosc Int Open ; 12(4): E467-E473, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38585018

RESUMO

Background and study aims The optimal number of needle passes during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) is not yet established. We aimed to perform a per-pass analysis of the diagnostic accuracy of EUS-FNB of solid pancreatic lesions using a 22G Franseen needle. Patients and methods Consecutive patients with solid pancreatic lesions referred to 11 Italian centers were prospectively enrolled. Three needle passes were performed; specimens were collected after each pass and processed individually as standard histology following macroscopic on-site evaluation (MOSE) by the endoscopist. The primary endpoint was diagnostic accuracy of each sequential pass. Final diagnosis was established based on surgical pathology or a clinical course of at least 6 months. Secondary endpoints were specimen adequacy, MOSE reliability, factors impacting diagnostic accuracy, and procedure-related adverse events. Results A total of 504 samples from 168 patients were evaluated. Diagnostic accuracy was 90.5% (85.0%-94.1%) after one pass and 97.6% (94.1%-99.3%) after two passes ( P =0.01). Similarly, diagnostic sensitivity and sample adequacy were significantly higher adding the second needle pass (90.2%, 84.6%-94.3% vs 97.5%, 93.8%-99.3%, P =0.009 and 91.1%, 85.7%-94.9% vs 98.2%, 95.8%-99.3%, P =0.009, one pass vs two passes, respectively). Accuracy, sensitivity, and adequacy remained the same after the third pass. The concordance between MOSE and histological evaluation was 89.9%. The number of passes was the only factor associated with accuracy. One case of mild acute pancreatitis (0.6%) was managed conservatively. Conclusions At least two passes should be performed for the diagnosis of solid pancreatic lesions. MOSE is a reliable tool to predict the histological adequacy of specimens.

3.
Endoscopy ; 56(4): 249-257, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38237633

RESUMO

INTRODUCTION: Endoscopic ultrasound (EUS)-guided drainage of symptomatic pancreatic fluid collections (PFCs) using the Hot-Axios device has recently been associated with a significant risk of bleeding. This adverse event (AE) seems to occur less frequently with the use of a different device, the Spaxus stent. The aim of the current study was to compare the rates of bleeding between the two stents. METHODS: Patients admitted for treatment of PFCs by EUS plus lumen-apposing metal stent in 18 endoscopy referral centers between 10 July 2019 and 28 February 2022 were identified and their outcomes compared using a propensity-matching analysis. RESULTS: 363 patients were evaluated. After a 1-to-1 propensity score match, 264 patients were selected (132 per group). The technical and clinical success rates were comparable between the two groups. Significantly more bleeding requiring transfusion and/or intervention occurred in the Hot-Axios group than in the Spaxus group (6.8% vs. 1.5%; P = 0.03); stent type was a significant predictor of bleeding in both univariate and multivariate regression analyses (P = 0.03 and 0.04, respectively). Bleeding necessitating arterial embolization did not however differ significantly between the two groups (3.0% vs. 0%; P = 0.12). In addition, the Hot-Axios was associated with a significantly higher rate of overall AEs compared with the Spaxus stent (9.8% vs. 3.0%; P = 0.04). CONCLUSION: Our study showed that, in patients with PFCs, bleeding requiring transfusion and/or intervention occurred significantly more frequently with use of the Hot-Axios stent than with the Spaxus stent, although this was not the case for bleeding requiring embolization.


Assuntos
Pâncreas , Pancreatopatias , Humanos , Estudos Retrospectivos , Stents/efeitos adversos , Endossonografia/efeitos adversos , Drenagem/efeitos adversos , Hemorragia/etiologia , Endoscopia Gastrointestinal , Resultado do Tratamento
4.
World J Gastroenterol ; 30(1): 70-78, 2024 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-38293324

RESUMO

This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) as a salvage approach in cases of unsuccessful conventional management. EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery. The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events, making it a safe and effective option for appropriate candidates. Furthermore, EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture. However, patient selection is critical for the success of EUS-GBD, and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure. As the field continues to evolve and mature, ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD, ultimately leading to improved outcomes for patients.


Assuntos
Colecistite Aguda , Vesícula Biliar , Humanos , Vesícula Biliar/diagnóstico por imagem , Vesícula Biliar/cirurgia , Stents , Endossonografia/métodos , Drenagem/efeitos adversos , Drenagem/métodos , Colecistite Aguda/cirurgia , Ultrassonografia de Intervenção , Resultado do Tratamento
5.
Dig Endosc ; 36(3): 351-358, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37253185

RESUMO

OBJECTIVES: Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in patients with distal malignant biliary obstruction (DMBO). Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. In a palliative setting the endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) could represent an easy and valid option. We performed a prospective study with a new EC-LAMS with the primary aim to assess the clinical success rate of EUS-GBD as a first-line approach to the palliation of DMBO. METHODS: In all, 37 consecutive patients undergoing EUS-GBD with a new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease >15% within 24 h and >50% within 14 days after EC-LAMS placement. RESULTS: The mean age was 73.5 ± 10.8 years; there were 17 male patients (45.9%). EC-LAMS placement was technically feasible in all patients (100%) and the clinical success rate was 100%. Four patients (10.8%) experienced adverse events, one bleeding, one food impaction, and two cystic duct obstructions because of disease progression. No stent-related deaths were observed. The mean hospitalization was 7.7 ± 3.4 days. Median overall survival was 4 months (95% confidence interval 1-8). CONCLUSION: Endoscopic ultrasound-guided gallbladder drainage with the new EC-LAMS is a valid option in palliative endoscopic biliary drainage as a first-step approach in low survival patients with malignant jaundice unfit for surgery. A smaller diameter EC-LAMS should be preferred, particularly if the drainage is performed through the stomach, to avoid potential food impaction, which could result in stent dysfunction.


Assuntos
Colestase , Icterícia , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Vesícula Biliar , Estudos Prospectivos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Endossonografia/métodos , Icterícia/complicações , Drenagem/métodos , Stents/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ultrassonografia de Intervenção/métodos
6.
Endoscopy ; 56(1): 31-40, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37591258

RESUMO

BACKGROUND: There is limited evidence on the comparative diagnostic performance of endoscopic tissue sampling techniques for subepithelial lesions. We performed a systematic review with network meta-analysis to compare these techniques. METHODS: A systematic literature review was conducted for randomized controlled trials (RCTs) comparing the sample adequacy and diagnostic accuracy of bite-on-bite biopsy, mucosal incision-assisted biopsy (MIAB), endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and EUS-guided fine-needle biopsy (FNB). Results were expressed as relative risk (RR) and 95%CI. RESULTS: Eight RCTs were identified. EUS-FNB was significantly superior to EUS-FNA in terms of sample adequacy (RR 1.20 [95%CI 1.05-1.45]), whereas none of the other techniques significantly outperformed EUS-FNA. Additionally, bite-on-bite biopsy was significantly inferior to EUS-FNB (RR 0.55 [95%CI 0.33-0.98]). Overall, EUS-FNB appeared to be the best technique (surface under cumulative ranking [SUCRA] score 0.90) followed by MIAB (SUCRA 0.83), whereas bite-on-bite biopsy showed the poorest performance. When considering lesions <20 mm, MIAB, but not EUS-FNB, showed significantly higher accuracy rates compared with EUS-FNA (RR 1.68 [95%CI 1.02-2.88]). Overall, MIAB ranked as the best intervention for lesions <20 mm (SUCRA score 0.86 for adequacy and 0.91 for accuracy), with EUS-FNB only slightly superior to EUS-FNA. When rapid on-site cytological evaluation (ROSE) was available, no difference between EUS-FNB, EUS-FNA, and MIAB was observed. CONCLUSION: EUS-FNB and MIAB appeared to provide better performance, whereas bite-on-bite sampling was significantly inferior to the other techniques. MIAB seemed to be the best option for smaller lesions, whereas EUS-FNA remained competitive when ROSE was available.


Assuntos
Neoplasias Pancreáticas , Ferida Cirúrgica , Trato Gastrointestinal Superior , Humanos , Metanálise em Rede , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endoscopia , Trato Gastrointestinal Superior/patologia , Neoplasias Pancreáticas/patologia
7.
Diagnostics (Basel) ; 13(21)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37958236

RESUMO

Aims: Lumen-apposing metal stents (LAMSs) in ultrasonography-guided gallbladder drainage (EUS-GBD) have become increasingly important for high-risk surgical patients. Our study aims to evaluate the technical and clinical success, safety, and feasibility of endoscopic ultrasonography-guided gallbladder drainage using a new dedicated LAMS. Methods: This is a retrospective multicenter study that included all consecutive patients not suitable for surgery who were referred to a tertiary center for EUS-GBD using a new dedicated electrocautery LAMS for acute cholecystitis at eight different centers. Results: Our study included 54 patients with a mean age of 76.48 years (standard deviation: 12.6 years). Out of the 54 endoscopic gallbladder drainages performed, 24 (44.4%) were cholecysto-gastrostomy, and 30 (55.4%) were cholecysto-duodenostomy. The technical success of LAMS placement was 100%, and clinical success was achieved in 23 out of 30 patients (76.67%). Adverse events were observed in two patients (5.6%). Patients were discharged after a median of 5 days post-stenting. Conclusions: EUS-GBD represents a valuable option for high-surgical-risk patients with acute cholecystitis. This new dedicated LAMS has demonstrated a high rate of technical and clinical success, along with a high level of safety.

9.
Gastrointest Endosc ; 98(5): 765-773, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37392954

RESUMO

BACKGROUND AND AIMS: EUS-guided gallbladder drainage (EUS-GBD) with lumen-apposing metal stents (LAMSs) has been reported as a rescue treatment with encouraging results for the relief of jaundice in patients with distal malignant biliary obstruction (DMBO) and after failure of both ERCP and EUS-guided choledochoduodenostomy. METHODS: This was a multicenter retrospective analysis of all cases of consecutive EUS-GBD with LAMSs used as a rescue treatment for patients with DMBO in 14 Italian centers from June 2015 to June 2020. Primary endpoints were technical and clinical success, whereas the secondary endpoint was the adverse event (AE) rate. RESULTS: Forty-eight patients (52.1% women) with a mean age of 74.3 ± 11.7 years were included in the study. Biliary stricture was related to pancreatic adenocarcinoma (85.4%), duodenal adenocarcinoma (2.1%), cholangiocarcinoma (4.2%), ampullary cancer (2.1%), colon cancer (4.2%), and metastatic breast cancer (2.1%). The mean diameter of the common bile duct was 13.3 ± 2.8 mm. LAMSs were placed transgastrically in 58.3% of cases and transduodenally in 41.7%. Technical success was 100%, whereas clinical success was 81.3%, with a mean total bilirubin reduction after 2 weeks of 66.5%. The mean procedure time was 26.4 minutes, and the mean hospital stay was 9.2 ± 8.2 days. AEs occurred in 5 patients (10.4%): 3 were classified as intraprocedural and 2 were classified as delayed because they occurred after >15 days. When the American Society for Gastrointestinal Endoscopy lexicon was used, 2 AEs were mild and 3 were moderate (2 buried LAMSs). The mean follow-up was 122 days. CONCLUSIONS: Our study shows that EUS-GBD with LAMSs used as a rescue treatment for patients affected by DMBO represents a valuable option in terms of technical and clinical success rates, with an acceptable AE rate. To the best of our knowledge, this is the largest study concerning the use of this procedure. (Clinical trial registration number: NCT03903523.).


Assuntos
Adenocarcinoma , Ampola Hepatopancreática , Colestase , Neoplasias do Ducto Colédoco , Neoplasias Pancreáticas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Vesícula Biliar , Estudos Retrospectivos , Adenocarcinoma/complicações , Neoplasias Pancreáticas/complicações , Neoplasias do Ducto Colédoco/complicações , Endossonografia/métodos , Stents/efeitos adversos , Colestase/etiologia , Colestase/cirurgia , Drenagem/métodos , Ultrassonografia de Intervenção/efeitos adversos , Resultado do Tratamento
10.
Ann Gastroenterol ; 36(3): 257-266, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37144012

RESUMO

Endoscopic ultrasound (EUS) offers the ability to obtain tissue material via a fine needle under direct visualization for cytological or pathological examination. Prior studies have looked at EUS tissue acquisition; however, most reports have been centered around lesions of the pancreas. This paper aims to review the literature on EUS tissue acquisition in other organs (beyond the pancreas) such as the liver, biliary tree, lymph nodes, and upper and lower gastrointestinal tracts. Furthermore, techniques for obtaining tissue samples under EUS guidance continue to evolve. Specifically, some of the techniques that endoscopists employ are suction techniques (i.e., dry heparin, dry suction technique, wet suction technique), the slow pull technique, and the fanning technique. Apart from acquisition techniques, the type and size of the needle utilized play a major role in the quality of samples. This review describes the indications for tissue acquisition for each organ, and also describes and compares the various tissue acquisition techniques, as well as the different needles used according to their shape and size.

11.
Gastroenterology ; 165(1): 244-251.e3, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37061169

RESUMO

BACKGROUND & AIMS: Both computer-aided detection (CADe)-assisted and Endocuff-assisted colonoscopy have been found to increase adenoma detection. We investigated the performance of the combination of the 2 tools compared with CADe-assisted colonoscopy alone to detect colorectal neoplasias during colonoscopy in a multicenter randomized trial. METHODS: Men and women undergoing colonoscopy for colorectal cancer screening, polyp surveillance, or clincial indications at 6 centers in Italy and Switzerland were enrolled. Patients were assigned (1:1) to colonoscopy with the combinations of CADe (GI-Genius; Medtronic) and a mucosal exposure device (Endocuff Vision [ECV]; Olympus) or to CADe-assisted colonoscopy alone (control group). All detected lesions were removed and sent to histopathology for diagnosis. The primary outcome was adenoma detection rate (percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, advanced adenomas and serrated lesions detection rate, the rate of unnecessary polypectomies (polyp resection without histologically proven adenomas), and withdrawal time. RESULTS: From July 1, 2021 to May 31, 2022, there were 1316 subjects randomized and eligible for analysis; 660 to the ECV group, 656 to the control group). The adenoma detection rate was significantly higher in the ECV group (49.6%) than in the control group (44.0%) (relative risk, 1.12; 95% CI, 1.00-1.26; P = .04). Adenomas detected per colonoscopy were significantly higher in the ECV group (mean ± SD, 0.94 ± 0.54) than in the control group (0.74 ± 0.21) (incidence rate ratio, 1.26; 95% CI, 1.04-1.54; P = .02). The 2 groups did not differ in term of detection of advanced adenomas and serrated lesions. There was no significant difference between groups in mean ± SD withdrawal time (9.01 ± 2.48 seconds for the ECV group vs 8.96 ± 2.24 seconds for controls; P = .69) or proportion of subjects undergoing unnecessary polypectomies (relative risk, 0.89; 95% CI, 0.69-1.14; P = .38). CONCLUSIONS: The combination of CADe and ECV during colonoscopy increases adenoma detection rate and adenomas detected per colonoscopy without increasing withdrawal time compared with CADe alone. CLINICALTRIALS: gov, Number: NCT04676308.


Assuntos
Adenoma , Neoplasias Colorretais , Masculino , Humanos , Feminino , Colonoscopia , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/patologia , Mucosa , Computadores
12.
J Clin Med ; 12(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37109171

RESUMO

Many tumors may secondarily involve the pancreas; however, only retrospective autopic and surgical series are available. We retrospectively collected data from all consecutive patients with histologically confirmed secondary tumors of the pancreas referred to five Italian centers between 2010 and 2021. We described clinical and pathological features, therapeutic approach and treatment outcomes. EUS characteristics of the lesions and the tissue acquisition procedures (needle, passages, histology) were recorded. A total of 116 patients (males/females 69/47; mean age 66.7) with 236 histologically confirmed pancreatic metastases were included; kidney was the most common primary site. EUS was performed to confirm the diagnosis in 205 lesions which presented as predominantly solitary (59), hypoechoic (95) and hypervascular (60), with a heterogeneous (n = 54) pattern and well-defined borders (n = 52). EUS-guided tissue acquisition was performed in 94 patients with an overall accuracy of 97.9%. Histological evaluation was possible in 88.3% of patients, obtaining final diagnosis in all cases. When cytology alone was performed, the final diagnosis was obtained in 83.3% of cases. A total of 67 patients underwent chemo/radiation therapy, and surgery was attempted in 45 (38.8%) patients. Pancreatic metastases are a possible event in the natural history of solid tumors, even long after the diagnosis of the primary site. EUS-guided fine needle biopsy may be suggested to implement the differential diagnosis.

13.
Dig Liver Dis ; 55(5): 644-648, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36890050

RESUMO

BACKGROUND AND AIM: Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for the treatment of gastric outlet obstruction (GOO) has been actually performed only with one type of electrocautery lumen-apposing metal stents (EC-LAMS). We aimed to evaluate the safety, technical and clinical effectiveness of EUS-GE using a newly available EC-LAMS in patients with malignant and benign GOO. MATERIALS AND METHODS: Consecutive patients who underwent EUS-GE for GOO using the new EC-LAMS at five endoscopic referral centers were retrospectively evaluated. Clinical efficacy was determined utilizing the Gastric Outlet Obstruction Scoring System (GOOSS). RESULTS: Twenty-five patients (64% male, mean age 68.7 ± 9.3 years) met the inclusion criteria; 21 (84%) had malignant etiology. Technically, EUS-GE was successful in all patients, with a mean procedural time of 35 ± 5 min. Clinical success was 68% at 7 days and 100% at 30 days. The mean time to resume oral diet was 11.4 ± 5.8 h, with an improvement of at least one point of GOOSS score observed in all patients. The median hospital stay was 4 days. No procedure-related adverse events occurred. After a mean follow-up of 7.6 months (95% CI 4.6-9.2), no stent dysfunctions were observed. CONCLUSION: This study suggests EUS-GE can be performed safely and successfully using the new EC-LAMS. Future large multicenter prospective studies are needed to confirm our preliminary data.


Assuntos
Obstrução da Saída Gástrica , Ultrassonografia de Intervenção , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Eletrocoagulação/efeitos adversos , Endossonografia , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Gastroenterostomia/efeitos adversos , Estudos Retrospectivos , Stents/efeitos adversos
14.
Cancers (Basel) ; 15(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36980675

RESUMO

There is a paucity of evidence regarding whether biliary stents influence endoscopic ultrasound-guided tissue acquisition using either fine-needle biopsy (EUS-FNB) or fine-needle aspiration (EUS-FNA), among patients with head of pancreas (HOP) lesions. We aimed at assessing the diagnostic accuracy of endoscopic ultrasound-guided tissue sampling in patients with or without bile duct stents. A total of seven studies with 2458 patients were included. The main aim was to assess overall pooled diagnostic accuracy. A pairwise meta-analysis was performed using a random effects model. Outcomes were expressed as odds ratios (ORs) with 95% confidence intervals (CIs). We found that pooled accuracy was 85.4% (CI 78.8-91.9) and 88.1% (CI 83.3-92.9) in patients with and without stents, respectively. There was no statistically significant difference between the two (OR 0.74; p = 0.07). Furthermore, patients with metal stents demonstrated a significant difference (OR 0.54, 0.17-0.97; p = 0.05), which was not seen with plastic stents. EUS-FNB showed poorer diagnostic accuracy with concurrent biliary stenting (OR 0.64, 0.43-0.95; p = 0.03); however, the same was not observed with EUS-FNA. Compared to plastic stents, metal biliary stenting further impacted the diagnostic accuracy of EUS-guided tissue acquisition for pancreatic head lesions. There was no difference in the rate of procedure-related adverse events between the stent and no-stent groups.

15.
Gastrointest Endosc ; 98(2): 191-198, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36990125

RESUMO

BACKGROUND AND AIMS: The role of the newer EUS fine-needle biopsy needles in lymphadenopathies (LAs) is still under evaluation. We aimed to evaluate the diagnostic accuracy and adverse event rate of EUS-guided fine-needle biopsy sampling (EUS-FNB) in diagnosing LAs. METHODS: From June 2015 to June 2022, all patients referred to 4 institutions for EUS-FNB of mediastinal and abdominal LAs were enrolled. Twenty-two-gauge Franseen tip or 25-gauge fork-tip needles were used. The criterion standard for positive results was surgery or imaging and clinical evolution over a follow-up of at least 1 year. RESULTS: One hundred consecutive patients were enrolled, consisting of those with a new diagnosis of LA (40%), presence of LA with a previous history of neoplasia (51%), or suspected lymphoproliferative disease (9%). EUS-FNB was technically feasible in all LA patients with 2 to 3 passes (mean, 2.62 ± .93). The overall sensitivity, positive predictive value, specificity, negative predictive value, and accuracy for EUS-FNB were 96.20%, 100%, 100%, 87.50%, and 97.00%, respectively. Histologic analysis was feasible in 89% of cases. Cytologic evaluation was performed in 67% of specimens. A statistical difference between the accuracy of the 22-gauge or 25-gauge needle (P = .63) was not found. A subanalysis on lymphoproliferative disease revealed a sensitivity and accuracy of 89.29% and 90.0%, respectively. No adverse events were recorded. CONCLUSIONS: EUS-FNB with new end-cutting needles is a valuable and safe method to diagnose LAs. The high quality of histologic cores and the good amount of tissue allowed a complete immunohistochemical analysis of metastatic LAs and precise subtyping of the lymphomas. (Clinical trial registration number: NCT02855151.).


Assuntos
Linfadenopatia , Linfoma , Neoplasias , Neoplasias Pancreáticas , Humanos , Estudos Prospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Linfadenopatia/diagnóstico , Linfoma/diagnóstico , Linfoma/patologia , Neoplasias Pancreáticas/patologia
16.
Gastrointest Endosc ; 97(5): 839-848.e5, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36657607

RESUMO

BACKGROUND AND AIMS: Evidence is limited on the comparative diagnostic performance of tissue sampling techniques for EUS-guided fine-needle biopsy sampling of pancreatic masses. We performed a systematic review with network meta-analysis to compare these techniques. METHODS: Rates of sample adequacy, blood contamination, and tissue integrity using fine-needle biopsy sampling needles were evaluated. Direct and indirect comparisons were performed among the slow-pull, dry-suction, modified wet-suction, or no-suction techniques. Results are expressed as risk ratio (RR) and 95% confidence interval (CI). RESULTS: Overall, 9 randomized controlled trials (756 patients) were identified. On network meta-analysis, the no-suction technique was significantly inferior to the other techniques (RR, .85 [95% CI, .78-.92] vs slow pull; RR, .85 [95% CI, .78-.92] vs dry suction; RR, .83 [95% CI, .76-.90] vs modified wet suction) in terms of sample adequacy. Consequently, modified wet suction was shown to be the best technique (surface under the cumulative ranking curve score, .90), with the no-suction technique showing poorer performance in terms of sample adequacy (surface under the cumulative ranking curve score, .14). Dry suction was associated with significantly higher rates of blood contamination as compared with the slow-pull technique (RR, 1.44; 95% CI, 1.15-1.80), whereas no suction led to less blood contamination of samples in comparison with other techniques (RR, .71 [95% CI, .52-.97] vs slow pull; RR, .49 [95% CI, .36-.66] vs dry suction; RR, .57 [95% CI, .40-.81] vs modified wet suction). The modified wet-suction technique significantly outperformed dry suction in terms of tissue integrity of the sample (RR, 1.36; 95% CI, 1.06-1.75). CONCLUSIONS: Modified wet suction seemed to provide high rates of integrity and adequate samples, albeit with high blood contamination. The no-suction technique performed significantly worse than other sampling strategies.


Assuntos
Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Metanálise em Rede , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Sucção/métodos
17.
Dig Dis ; 41(5): 819-821, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36596281

RESUMO

Gastric outlet obstruction is a condition characterized by inadequate gastric emptying due to benign or malignant conditions inducing an inadequate oral intake. In recent years, a novel therapeutic treatment for this condition is given by the use of electrocautery lumen-apposing metal stents. In this case report, we want to present an example of a benign condition treated by endoscopic ultrasound-guided gastroenterostomy with the bi-flanged SpaxusTM stent (Taewoong Medical Co.) mounted on electrocautery catheter.


Assuntos
Obstrução da Saída Gástrica , Ultrassonografia de Intervenção , Humanos , Ultrassonografia de Intervenção/efeitos adversos , Endossonografia/efeitos adversos , Gastroenterostomia/efeitos adversos , Obstrução da Saída Gástrica/diagnóstico por imagem , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Stents/efeitos adversos
18.
Cancers (Basel) ; 15(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36672438

RESUMO

Malignant biliary obstruction (MBO) is a challenging medical problem that often negatively impacts the patient's quality of life (QoL), postoperative complications, and survival rates. Endoscopic approaches to biliary drainage are generally performed by ERCP or, in selected cases, with a percutaneous transhepatic biliary drainage (PTBD). Recent advances in therapeutic endoscopic ultrasound (EUS) allow drainage where previous methods have failed. EUS has evolved from a purely diagnostic technique to one that allows a therapeutic approach in the event of ERCP failure in distal MBO. Moreover, the introduction of dedicated accessories and prostheses for EUS-guided transmural biliary drainage (EUS-BD) made these procedures more successful with regard to technical success, clinical outcomes and reduction of adverse events (AEs). Finally, lumen-apposing metal stents (LAMS) have improved the therapeutic role of the EUS. Subsequently, the electrocautery enhanced tip of the LAMS (EC-LAMS) allows a direct access of the delivery system to the target lumen, thereby simplifying and reducing the EUS-BD procedure time. EUS-BD using LAMS and EC-LAMS has proven effective and safe with a low rate of AEs. This review aims to evaluate biliary drainage techniques in malignant obstruction, focusing on the role of EUS biliary drainage by LAMS.

19.
Diagnostics (Basel) ; 13(2)2023 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-36673049

RESUMO

Pancreatic neuroendocrine tumor (PNET) behavior assessment is a daily challenge for physicians. Modern PNET management varies from a watch-and-wait strategy to surgery depending on tumor aggressiveness. Therefore, the aggressiveness definition plays a pivotal role in the PNET work-up. The aggressiveness of PNETs is mainly based on the dimensions and histological grading, with sometimes a lack of specificity and sensibility. In the last twenty years, EUS has become a cornerstone in the diagnostic phase of PNET management for its high diagnostic yield and the possibility of obtaining a histological specimen. The number of EUS applications in the PNET work-up has been rapidly increasing with new and powerful possibilities. The application of contrast has led to an important step in PNET detection; in recent years, it has been gaining interesting applications in aggressiveness assessment. In this review, we underline the latest experiences and opportunities in the behavior assessment of PNETs using contact-enhanced EUS and contested enhanced harmonic EUS with a particular focus on the future application and possibility that these techniques could provide.

20.
Eur J Gastroenterol Hepatol ; 35(2): 153-158, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36574305

RESUMO

BACKGROUND AND AIM: The diagnostic role of endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and fine needle biopsy (FNB) of pelvic masses has not been well established. We aimed to evaluate the diagnostic accuracy of EUS plus FNA/FNB in suspected local recurrence of pelvic masses. MATERIALS AND METHODS: All consecutive patients with a history of lower gastrointestinal and pelvic mass undergone EUS-FNA/FNB were included in the study. RESULTS: In total 34 patients who underwent EUS-guided FNA or FNB of a perirectal mass were enrolled. The sampled lesion was a mass in 22 patients (64.7%) and a lymph node in 10 patients (29.4%). The univariate logistic regression analysis for diagnostic accuracy showed lesion size as a significant predictor of diagnostic accuracy [odds ratio (OR), 1.61; 1.08-2.27; P = 0.02]. Diagnostic sensitivity was 100% (71.5-100%) with EUS-FNB and 75% (34.9-96.8%) with EUS-FNA ( P = 0.12); specificity was 100% in both groups ( P = 1.0). Sample adequacy was 94.1% in the whole cohort, with 20/20 adequacy rate (100%) in the EUS-FNB group and 12/14 (85.7%) in the EUS-FNA group ( P = 0.28). CONCLUSION: This is the first study demonstrating the diagnostic yield of EUS plus FNA/FNB in patients with pelvic masses comparing the two needles. Our results highlight the relevance of this technique, especially in undefined masses during oncological follow-up.


Assuntos
Endossonografia , Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA